Please use this identifier to cite or link to this item:
http://arks.princeton.edu/ark:/88435/dsp019019s539k
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Meggers, Forrest | - |
dc.contributor.author | Guo, Hongshan | - |
dc.contributor.other | Architecture Department | - |
dc.date.accessioned | 2020-07-13T02:01:09Z | - |
dc.date.available | 2021-11-04T16:54:15Z | - |
dc.date.issued | 2019 | - |
dc.identifier.uri | http://arks.princeton.edu/ark:/88435/dsp019019s539k | - |
dc.description.abstract | Energy has been delivered to buildings and households to make sure rooms are comfortable for occupants. We currently think of this delivery in the isolation as it heats and cools individual spaces. The heating and cooling of buildings have consequently become more about hitting a setpoint instead of aligning the delivery of comfort to humans with the effective and readily available upstream sources. The thesis of this dissertation is finding the most effective pathway to supply comfort to people. The work begins with the examination of the fundamental assumptions of thermal comfort models using an exergetic approach to insert the occupants into the energy delivery chain. Second, the research examines how environmental parameters such as relative humidity and mean radiant temperatures are oversimplified in energy analyses. Finally, this is connected with the analysis of sourcing the supplied exergy accordingly was also investigated within the scope of this dissertation. The research is organised into three corresponding sections, each containing three projects. In the first section, a conceptual energy delivery framework was proposed, upon which the feasibility of using human body exergy model was investigated and a new analytical human body exergy model proposed. Varying certain inputs to the model, such as the relative humidity and the mean radiant temperature, can cause the results of the human body exergy model to vary significantly. Unlike relative humidity, mean radiant temperature is more challenging to measure and model. This radiant connection between the occupants and their surroundings is the focus of the second section. Beginning with a critique on the spatial limitations of conventional measurement techniques of mean radiant temperature, a comprehensive review of the complexity and challenges of modeling and measuring mean radiant temperature is presented. Its coupled relationship with air temperature was also investigated in a subsequent project. Finally, the third section begins by tracing back to the thermal sources such as geothermal for optimal temperatures. It then attempts to rearrange the energy delivery system by matching the supply and demand of energy concerning not only their amounts but usabilities - or exergy - to create a flow model from source to comfort. | - |
dc.language.iso | en | - |
dc.publisher | Princeton, NJ : Princeton University | - |
dc.relation.isformatof | The Mudd Manuscript Library retains one bound copy of each dissertation. Search for these copies in the library's main catalog: <a href=http://catalog.princeton.edu> catalog.princeton.edu </a> | - |
dc.subject | comfort delivery | - |
dc.subject | energy delivery | - |
dc.subject | exergy analysis | - |
dc.subject | mean radiant temperature | - |
dc.subject | thermal comfort | - |
dc.subject.classification | Architectural engineering | - |
dc.subject.classification | Energy | - |
dc.subject.classification | Architecture | - |
dc.title | Energy Delivery Reconditioned for Thermal Comfort | - |
dc.type | Academic dissertations (Ph.D.) | - |
pu.embargo.terms | 2021-06-10 | - |
Appears in Collections: | Architecture |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Guo_princeton_0181D_13020.pdf | 71.69 MB | Adobe PDF | View/Download |
Items in Dataspace are protected by copyright, with all rights reserved, unless otherwise indicated.