Please use this identifier to cite or link to this item:
http://arks.princeton.edu/ark:/88435/dsp011544br79n
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hvasta, M. G. | - |
dc.contributor.author | Dudt, D. | - |
dc.contributor.author | Fisher, A. E. | - |
dc.contributor.author | Kolemen, E. | - |
dc.date.accessioned | 2018-06-12T17:28:19Z | - |
dc.date.available | 2018-06-12T17:28:19Z | - |
dc.date.issued | 2018-05-29 | - |
dc.identifier.uri | http://arks.princeton.edu/ark:/88435/dsp011544br79n | - |
dc.description.abstract | A 'weighted magnetic bearing' has been developed to improve the performance of rotating Lorentz-force flowmeters (RLFFs). Experiments have shown that the new bearing reduces frictional losses within a double-sided, disc-style RLFF to negligible levels. Operating such an RLFF under 'frictionless' conditions provides two major benefits. First, the steady-state velocity of the RLFF magnets matches the average velocity of the flowing liquid at low flow rates. This enables an RLFF to make accurate volumetric flow measurements without any calibration or prior knowledge of the fluid properties. Second, due to minimized frictional losses, an RLFF is able to measure low flow rates that cannot be detected when conventional, high-friction bearings are used. This paper provides a brief background on RLFFs, gives a detailed description of weighted magnetic bearings, and compares experimental RLFF data to measurements taken with a commercially available flowmeter. | en_US |
dc.description.tableofcontents | Read me and data files. | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Princeton Plasma Physics Laboratory, Princeton University | en_US |
dc.relation | Measurement Science and Technology, 2018, vol. 29, p. 075303 | en_US |
dc.relation.isreferencedby | https://doi.org/10.1088/1361-6501/aac3b5 | en_US |
dc.subject | low-friction bearings | en_US |
dc.subject | Lorentz-force velocimetry | en_US |
dc.subject | flowmeter | en_US |
dc.subject | liquid metal | en_US |
dc.title | Calibrationless rotating Lorentz-force flowmeters for low flow rate applications | en_US |
dc.type | Dataset | en_US |
pu.projectgrantnumber | 31016 G0001 10003086 101 | - |
pu.depositor | Stratton, Brent | - |
dc.contributor.funder | U. S. Department of Energy contract number DE-AC02-09CH11466 | en_US |
Appears in Collections: | Plasma Science & Technology |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Plot_Data_Hvasta_MST_2018.xlsx | 80.06 kB | Microsoft Excel XML | View/Download | |
Readme.rtf | 1.61 kB | RTF | View/Download |
Items in Dataspace are protected by copyright, with all rights reserved, unless otherwise indicated.